Explore
Ampetronic Ear Symbol
Home // ILD300 Professional rack mountable loop driver

ILD300 Professional rack mountable loop driver

The ILD300 is a professional audio induction loop driver capable of driving loop areas in excess of 400m2 with an unsurpassed clarity of sound for both music and speech for superior intelligibility.

Based on proven and highly reliable technology it is backed by an unrivalled 5 year warranty and free technical support. Improved power output provides outstanding value without compromise.

It has all the usual high quality features found on Ampetronic equipment such as metal loss correction and speech optimised gain control. The ILD300 is very compact and elegant, suitable for freestanding, wall mounting
or rack mounting.

Applications include

  • Conference facilities
  • Theatres
  • Sports halls
  • Educational environments
  • Places of worship
  • Lecture Halls

Equipment supplied as standard with the ILD300

  • Handbook and installation instructions
  • 197 x 252mm loop system present sign (deaf logo)
  • Region specific mains cable
  • Loop connector

Product Code:
ILD300

  • Features
  • Accessories
  • Specifications
  • Standards
  • Downloads
    • Area coverage to >400 m2
    • Low lifetime cost
      Excellent proven reliability
      5 year warranty
    • Unparalleled sound quality
      Excellent intelligibility
      Speech optimised gain control
      High voltage headroom avoids high frequency clipping
    • Metal loss corrector corrects frequency dependent loss from metal structures
    • Very compact: 215 x 220 x 44 mm
    • Microphone (XLR) and line inputs
    • Extensive input adaptors available for any audio input requirements
    • Free technical support line for advice, design and install
  • ILD300 optional accessories

    Ampetronic can supply an extensive range of additional accessories for installation – discuss your requirements with our sales team and we will provide materials and equipment to suit your application.

    Input adaptorsA range of input adaptors and interface cables to accept most audio source inputs, see table below
    Installation Accessories18mm x 0.25mm copper tape
    PVC extrusion to protect copper tape
    Installation / warning tape to fix cable or tape to a floor
    Wall mount bracketsWML1-U
    Rack mount bracketsRM-1U
    Phase shifterSP5 for an array system requires a design which can be provided by Ampetronic

    Input adaptors and preamplifiers

    By using the appropriate input adaptor or preamplifier the ILD300 will accept multiple additional inputs or audio inputs from other sources:

    Input typeAdaptor
    Additional microphone and / or line inputsMP221 preamps can drive up to 2 mics + 2 line inputs
    100V line input
    Low impedance speaker line
    Line Level
    ATT-UJ & ATT-UX transformer isolated attenuators
    Unbalanced microphonesMAT1 adaptor

     

  • Perimeter Loops – Area Coverage (maximum)

    Room aspect ratio1:12:13:1
    Maximum area m2250310420

    For any Induction Loop System, area coverage is dependent on several factors. Please check these assumptions and contact Ampetronic for advice if required:

    • Loop must be 1-2m above or below the receiver height
    • There should be no metal structures in the plane of the loop
    • Sufficient voltage to drive the loop – check the cable table below

    Maximum Cable Length

    The ILD300 is designed for SINGLE TURN loops for optimum audio quality.

    • Loops with DC resistance from 0.2 to 1.2Ω
    • Impedance up to a maximum of 1.3Ω

    Maximum cable length is dependent on cable type and on the application:

    Cable typeMaximum Cable Length (m)
    Normal Use*Transient Speech*
    1.0mm2 copper4957
    2.5mm2 copper6785
    4.0mm2 copper7091
    1.8mm2 flat copper tape87101

     

    * Short term speech (e.g. service counter, airport PA system) can cope with limited clipping at high frequencies – Ampetronic recommends delivery of full current up to 1.2kHz for these applications.
    Longer term usage or signals with music or high quality audio must deliver full current to at least 1.6kHz to prevent fatigue and give acceptable intelligibility. Many commercially available systems do not deliver sufficient voltage to reproduce critical high frequencies – ask us for more details.

    ILD300 Specifications

    INPUTS

    Power35 W 230 V AC nominal, 45-65 Hz [120 V option available]
    Power switch and LED indicator on front panel
    Microphone inputXLR balanced microphone input for 200-600 Ω microphones;
    15 dB user selectable gain boost; + 15 V DC phantom power (selectable); sensitivity – 70 dBu; front panel recessed gain control
    Line input6.4 mm jack socket balanced line input; sensitivity – 30 dBu; overload protected; front panel recessed gain control
    Slave I/O6.4 mm jack insert point for connection of SP5 phase shifter
    0 dBu signal can be used for recording

    OUTPUTS

    Drive voltage6.4 Vrms (9.0V peak) at maximum output current
    Drive current4.9 Arms (7.0 Apk) continuous 1 kHz sine wave
    Short term peaks >10 A
    Front panel recessed control
    Drive current indicated on 4-LED display in 3 dB increments
    Loop connectorWieland ST17/2 (supplied)
    Loop MonitorProvides access to actual audio signal in loop
    3.5 mm stereo headphone connector on front panel

    THERMAL HEAT CHART

    Idle1/6 peak Output Current (Speech)1/3 peak Output Current (Pink noise)Full Power
    DriverChannelsCurrent (ARMS)Load Resistance (Ohms)AC In (W)BTUAC In (W)BTUAC In (W)BTUAC In (W)BTU
    ILD1000G19.21.5196550147115296320659
    ILD50016.41.515514614580227168366
    ILD30014.91.08271857329166142
    ILD12213.51.08271549247254142
    ILD100DC13.40.51.023619123720.450

     

    AUDIO SYSTEM

    Freq. response80 Hz to 6.5 kHz
    DistortionTHD+N
    Automatic Gain ControlThe AGC is optimised for speech. Range >36 dBu
    Front panel recessed input level control
    Metal loss correctionCorrects system frequency response due to metal structures in a building. Gain constant at 1 kHz, adjustable gain slope from
    0 to 3 dB per octave
    This does not compensate for signal loss from metal structures, which can be significant

    ADDITIONAL FUNCTIONS

    Fault MonitoringThree LED fault indicators on the front panel:
    • Overload – delivering over the rated current
    • Overheat – unit is too hot (mutes output signal)
    • Loop error – short circuit / open circuit error
    AncillaryTo supply Ampetronic ancillary units
    ±15 V DC 0.15 A power outlet on rear panel
    CoolingCooling is by natural convection from product casing

    PHYSICAL

    DimensionsHalf width 1U 19″ rack mount
    Width 215 mm Depth 220 mm Height 44 mm
    Mounting optionsFreestanding
    1U 19″ rack mount (requires additional rack tray)
    Wall mounting (requires additional brackets)
    Weight2.25kg
    EnvironmentIP 20 protection; 20 to 90% relative humidity; 0 to 35 ºC
  • The ILD300 is CE marked to all relevant safety and EMC standards.
    All Ampetronic amplifiers can be used to create a system that meets the requirements of IEC118-4 and the relevant recommendation of BS7594, however the design and installation of the system is equally important to meet these Induction Loop standards.
    Some Ampetronic products are CSA registered for sale in the USA and Canada – contact Ampetronic for details.

Related products

Explore all ampetronic products

Related Sectors

Explore all Sectors

Case studies

Explore 108 case studies