Explore
Ampetronic Ear Symbol
Home // HLS-2B driver with battery back-up

HLS-2B driver with battery back-up

The HLS-2B hearing loop driver features a DM2 Induction Loop driver in an advanced rugged amplifier enclosure primarily designed for lift/elevator applications or other industrial environments.

The HLS series units feature efficient class D current drive technology to reduce power consumption and heat output and are the only small area induction loop solutions capable of reliably driving most practical small area loops in high metal environments to meet the IEC60118-4 Standard.

The amplifier enclosure is constructed of a robust steel housing and the solution features a battery back-up in the the event of a power failure that will provide 12 hours of standby time and 2 hours in full operation. It is further protected by a 5 year warranty from Ampetronic.

The magnetic field strength and distribution in a lift car will be highly dependent on installation method and the construction of the lift car. It is strongly recommended that you contact Ampetronic for free technical support and advice on the best methodology and design for your specific application.

 

Product code:
HLS-2BUK

  • Features
  • Specifications
  • Downloads
    • Compact & lightweight
    • Class D Efficiency
    • Unrivalled Intelligibility
    • 2 transformer isolated inputs
    • Simple Integration
    • Full Area Coverage Lifts
    • Metal loss correction
    • Unrivalled intelligibility
    • Low lifetime cost
    • Excellent reliability, 5 year warranty & free technical support (NOTE battery is only covered by 1 year warranty)
    • 1:1 Potential area coverage of up to 36m2 Single turn 2.5mm wire floor level loop @ 1:1 ratio, 2m feed cable, no metal loss
    • 3:1 Potential area coverage of up to 29m2 Single turn 2.5mm wire, floor level loop @ 3:1 ratio,2m feed cable, no metal loss
    • 1:1 Practical lift application area coverage of up to 16m2 Ceiling mounted lift bars @ 2.1m height, 1m feed cable, 12dB metal loss
    • 1:1 Practical lift application area coverage of up to 12m2 Ceiling mounted lift bars @ 2.1m height, 2m feed cable, 12dB metal loss
  • INPUTS

    Power Supply

    Supply Voltage range:90-264V AC (Mains)
    Fuse:630mA (230V)

    1AT (120V)

    Power Consumption:230V AC Supply into rated load
    1.5mm2 solid core or untinned fine stranded wire.
    Indication:LED on PCB
    Connector:Fused screw terminal

    Input 1 & 2

    Connector:Wago 264 cage clamp for 0.78 – 2.5mm2 solid core or untinned fine stranded wire

    OUTPUTS

    Loop Output

    Connector:Wago 264 cage clamp for 0.78 – 2.5mm2 solid core or untinned fine stranded wire
    Compliance voltage:1.1VRMS (1.6Vpk)
    Max output current (sine):11ARMS
    Rated time for delivery:1min
    Rated temperature limited output current (pink):6ARMS
    Rated THD:<1%
    Output Impedance:>1Ω
    Current Adjustment:Full range
    Current Indication:LED indicates >3ARMS

    Loop Impedance

    0.1Ω to 0.2Ω, 0.14Ω reactive at 1.6 KHz

    Rated Load:9uH, 0.1R

    AUDIO SYSTEM

    Freq. Response100Hz to 5kHz ±1.5dB relative to 1kHz at low level, measured as loop current with no metal loss correction.
    Compression (AGC)Time constants optimised for speech
    (AGC) Dynamic range: >36dB
    Control: by adjusting input level/gain
    Indication: LED on PCB
    Metal Loss Correction0dB to 3dB / octave boost
    CorrectionAdjustable

    PHYSICAL

    Weight3kg
    EnvironmentIP22: <90% relative humidity, -20 to +50 °C (battery float life derates by 4% per °C above 25°C)
    DimensionsPower Option: 230V AC
    Width 158mm
    Length 366mm
    Height 49mm

     