Explore
Ampetronic Ear Symbol
Home // D14-2 networkable DSP hearing loop driver
Show product video

D14-2 networkable DSP hearing loop driver

The D Series represents the global benchmark for digital audio induction loop systems. The compact, elegant and sturdy units not only feature digital signal processing and networking functionality, but are also the most versatile and powerful solution available.

The D14-2 hearing loop amplifier is a 14 Amp dual output class ‘D’ driver; meaning a 60%+ increase in energy efficiency over existing solutions. Both drivers feature capacitive touch front panels with intuitive menus, built in test signals, and are fully networkable with a Wi-Fi accessible standard browser based control panel for remote set-up, monitoring and email alerts, and with Loopworks Measure LoopLink for easy test and commissioning.

The D14-2 features 14 Amps per loop output plus ample voltage headroom, making it the most flexible solution on the market, suitable for a huge range of applications. The added power of the D14-2 provides a solution for installations in environments containing very high levels of metal, previously not possible without the use of combiners.

In another first for high-power Class D Induction Loop drivers, installation can be performed with total confidence, as unique multi-stage filtering ensures compatibility with both other system equipment and global EMC regulations. The D Series also boasts Dual slope Metal Loss Control that caters for a wide range of metal loss frequency characteristics.

Product Code:
D14-2

 

Dante option available – see http://www.ampetronic.co/products/d14-2-dante-class-d-networkable-dsp-hearing-loop-amplifier/

  • Features
  • Specifications
  • Standards
  • Downloads
    • Drives 2 output channels at 14ARMS each, featuring accurate and stable 90° phase shift
    • Networkable with remote browser interface
    • Built-in test tones – controllable with LoopLink
    • Digital display & intuitive ‘touch’ menu system
    • 3 menu modes; Main, Status & Quick
    • Highly energy efficient Class-D amplifier with low heat dissipation
    • Up to 2 x 1,300m2 Perimeter Loops area coverage
    • Up to 3,300m2 MultiLoop Low Loss area coverage
    • Compact 1U rack mount unit with internal transformer for simple rack installation
    • Optimised for speech frequencies with unmatched intelligibility & capable of high quality musical reproduction
    • AGC & Dual Slope MLC
    • Active status monitoring & remote fault reporting via email
    • Data compliant with: IEC 62489-1 Standard
    Perimeter Loop Systems m2
    DriverMetal Loss1:1 Perimeter Loop3:1 Perimeter Loop
    D7-20dB2 x ≤4002 x ≤650
    5dBMax 5m widthMax 5m width
    D10-10dB≤1,000≤1,450
    10dBMax 5m widthMax 5m width
    D10-20dB2 x ≤1,0002 x ≤1,450
    -10dBMax 5m widthMax 5m width
    D14-20dB2 x ≤1,3002 x ≤1,450
    -10dBMax 5m widthMax 5m width

     

    MultiLoop Array Systems m2
    Metal LossNon Overlap MultiloopLoss Control MultiloopLow Spill Multiloop
    0dBD7-2 ≤1,7652 x ≤400Max 5m width2 x ≤650Max 5m width
    -5dBD7-2 ≤576
    D10-2 ≤625
    D7-2 ≤961
    D10-2 ≤1156
    D7-2 ≤841
    -10dBD14-2 ≤361D10-2 ≤625D10-2 ≤441
    -15dBD14-2 ≤289D14-2 ≤196

     

    Indicative metal loss scenarios are based on: 0db = a building with no structural metal, -5dB = a building with reinforced concrete (re-bar) construction, and -10dB = a room with steel raised access floor tiles, -15dB = a room with steel decking or reinforced concrete and raised access floor tiles.

    Multiloop area coverage calculations are based on the following assumptions: 1:1 room aspect ratio, 3mm2 copper tape laid at floor level, base current varies depending on solution employed.

  • INPUTS

    Power50/80/160W 230V AC nominal, 45-65Hz [120V option available]
    Power switch on front panel
    Fuse values: D10-1 120V – T1.6AL | 230V – T1AL
    Input 1 & 2
    Programmable Microphone / Line
    XLR balanced input switchable between microphone and line via menu

    Microphone specification: 200 – 600 Ω, sensitivity -64dBu

    Selectable 12V phantom power on microphone only

    Line sensitivity: -39dBu

    Input 2 can also be used for AES3 Digital Audio Signals

    Slave In6.35mm jack socket for linking more than one amplifier.
    Inserting plug disables other inputs

    OUTPUTS

    Loop Output Drive Voltage33.9VRMS (48Vpk) at maximum output current per channel
    Loop Output/Drive CurrentD7-X
    •7ARMS (10Apk) up to 60 seconds continuous 1kHz sine
    wave, peak >10A per channel
    • Cont. pink noise 3.3ARMS short term peaks >10A per ch.D10-X• 10ARMS (14.1Apk) up to 60 seconds continuous 1kHz sine
    wave, peak >14.1A per channel
    • Cont. pink noise 4.7ARMS short term peaks >14.1A per ch.D14-X 
    • 14ARMS (19.8Apk) up to 60 seconds continuous 1kHz sine
    wave, peak >19.8A per channel
    • Cont. pink noise 6.6ARMS short term peaks >20A per ch.
    • Level controlled via front panel menu or network
    • Drive current indicated on two 4-LED displays in 6dB increments
    Slave Out6.35mm jack socket to connect to other slave amplifiers
    Loop ConnectorsNeutrik NL2 Speakons (supplied) for each output
    Loop MonitorProvides access to monitor actual loop current via a
    3.5mm stereo headphone connector on front panel
    Channel A on left, channel B on right
    DC OutputResettable, fuse protected 12V 0.1A. Operation can be
    configured via menu.

    THERMAL HEAT CHART

    Idle1/6 peak Output Current (Speech)1/3 peak Output Current (Pink noise)Full Power
    Driver ModelNumber of channelsCurrent (Arms)Load Resistance (Ohms)AC In (W)BTUAC In (W)BTUAC In (W)BTUAC In (W)BTU
    D14-2214.00.4423784110790176317493
    D14-2214.01.2237859112167213736906
    D14-2210.02.423785285141117560273
    D10-2210.00.4418.463277652111163256
    D10-2210.01.218.463367688118337331
    D10-227.02.418.46332657371284167
    D10-1110.00.4713441749306791150
    D10-1110.01.0134421534681171242
    D10-117.02.0134419464166156198
    D7-227.00.441241321014411797184
    D7-227.01.012413510160130191317
    D7-225.02.01241287757119168232

     

     

     

    Audio System

    Frequency Response: 80Hz to 6.5kHz
    Distortion: THD+N <0.2% 1kHz sine at full current
    Automatic Gain Control: The AGC is optimised for speech. Dynamic range >36dB
    Metal Loss Correction: Corrects system frequency response due to metal structures in a building. Gain constant at 1kHz, adjustable gain slope from 0 to 4dB per octave in 0.25dB increments. Custom 2 slope MLC allows different slopes and transition frequency to be set via the menu.
    This does not compensate for signal loss from metal structures which can be significant.
    Phase Shift: User selectable at 0° or 90° between outputs

    Additional Functions

    Fault Monitoring:

    Indicators on the front panel:

    • Clipping – delivering over the rated voltage (per channel)
    • Error – Check status in menu

    Temperature and loop errors reported via the status menu

    Cooling: Variable speed fan cooled. Front inlet, rear exhaust.

    Physical

    Size: Full width 1U 19” rack mount. Width: 430mm Depth: 290mm Height: 44mm
    Mounting Options: Freestanding 1U 19” rack mount (brackets included)
    Weight:

    • D14-2: 6.9kg
    • D10-2: 5.5kg
    • D10-1: 4.37kg
    • D7-2: 4.62kg

    Environment: IP20 rated; 20 to 90% relative humidity; 0 to 35ºC

     

  • This product is designed to form part of a system that can meet all of the requirements of the international loop performance standard IEC60118-4, and the relevant parts of BS7594. To fully meet requirements of these standards, correct design, installation, commissioning and maintenance are required.

    All specification data has been compiled in accordance with IEC62489-1, the international standard for audio frequency induction loop equipment. Specification data should only be compared with data compliant to this standard.

    This product is CE and RCM marked to all relevant safety and EMC standards, and is NRTL (ETL) approved for sale in North America.

Related products

Explore all ampetronic products

Related Sectors

Explore all Sectors

Related case studies

1st Floor, Eiffel Tower

1st Floor, Eiffel Tower

Paris, France

Reliable and inexpensive.

Westminster Abbey

Westminster Abbey

London, United Kingdom

Those with hearing loss can enjoy the same experience

University of Sydney

University of Sydney

New South Wales, Australia

Provides equal access for those with hearing impairment

Liverpool Cathedral

Liverpool Cathedral

Liverpool, United Kingdom

Right solution for a complex set of requirements

Stonehenge

Stonehenge

Wiltshire, United Kingdom

Reception and information desks

Launceston airport

Launceston airport

Tasmania

Minimise metal loss effects

Canberra airport

Canberra airport

Australia

ILD series

New York Subway

New York Subway

NYC, United States

Genuine benefit to the hard of hearing people

Jodrell Bank

Jodrell Bank

Macclesfield, United Kingdom

Overspill control

Explore 107 case studies